Summit X150 Switches: Optics Support

Table last updated 8 August 2016

SFP TypePart No.Minimum ExtremeXOS Software VersionComments
LX SFP1005212.0.2.25
LX Industrial Grade SFP10052H12.0.2.25
SX SFP1005112.0.2.25
SX Industrial Grade SFP10051H12.0.2.25
ZX SFP1005312.0.2.25
ZX Industrial Grade SFP10053H15.2.2
LX100 SFP1006412.0.2.25
100BASE-BX SFP10058 / 1005912.0.2.25Used in –D & -U pairs
100BASE LX10 SFP1006612.0.2.25
100BASE-FX SFP for fast Ethernet ports1006712.0.2.25
1000BX SFP10056 / 1005712.0.2.25Used in –D & -U pairs

Summit X250e Switches: Optics Support

Table last updated 8 August 2016

SFP TypePart No.Minimum ExtremeXOS Software VersionComments
LX SFP1005212.0.2.25
LX Industrial Grade SFP10052H12.0.2.25
SX SFP1005112.0.2.25
SX Industrial Grade SFP10051H12.0.2.25
ZX SFP1005312.0.2.25
ZX Industrial Grade SFP10053H15.2.2
LX100 SFP1006412.0.2.25
100BASE-FX SFP for fast Ethernet ports1006712.0.2.25
100BASE BX SFP10058 / 1005912.0.2.25Used in –D & -U pairs
100BASE LX10 SFP1006612.0.2.25
1000BASE BX SFP10056 / 1005712.0.2.25Used in –D & -U pairs

Note: The XGM2-2sf ports are 10-Gb SFP+ ports and do not support 1-Gb optics (PD4-739782255).


Summit X350 Switches: Optics Support

Table last updated 8 August 2016

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005212.1.2
LX Industrial Grade SFP10052H12.1.2
SX SFP1005112.1.2
SX Industrial Grade SFP10051H12.1.2
ZX SFP1005312.1.2
ZX Industrial Grade SFP10053H15.2.2
LX100 SFP1006412.1.2
100FX SFP1006312.1.2
1000BASE BX SFP10056 / 1005712.1.2Used in –D & -U pairs
10/100/1000BASE-T copper SFP1006512.1.2Not supported on combo ports
10/100/1000BASE-T copper Industrial Grade SFP10070H15.2.1Not supported on combo ports
SFP+ (XGM2-2sf option card required)
ER SFP+1030912.3.3
LR SFP+1030212.2.1
SR SFP+1030112.2.1
LRM SFP+1030312.5.2.2
ZR SFP+1031015.2.2
SFP+ direct-attach passive copper cable (XGM2-2sf option card required)
1 meter1030412.2.1
3 meters1030512.2.1
5 meters1030612.2.1
10 meters1030712.2.1

Summit X430 Switches: Optics Support

Table last updated 23 October 2017

SFP TypePart No.Minimum ExtremeXOS Software VersionComments
LX SFP1005215.5.2.9
LX Industrial Grade SFP10052H15.5.2.9
SX SFP1005115.5.2.9
SX Industrial Grade SFP10051H15.5.2.9
ZX SFP1005315.5.2.9
ZX Industrial Grade SFP10053H15.5.2.9
LX100 SFP1006415.5.2.9
1000BASE BX SFP10056 / 1005715.5.2.9
1000BASE BX Industrial Grade SFP10056H / 10057H15.5.2.9
100BASE-FX SFP for fast Ethernet ports1006715.5.2.9
100BASE-LX10 SFP1006615.5.2.9
100BASE BX SFP10058 / 1005915.5.2.9Used in -D & -U pairs
10/100/1000BASE-T copper SFP1006515.5.2.9Not supported on combo ports
10/100/1000BASE-T copper Industrial Grade SFP10070H15.5.2.9Not supported on combo ports
100LX/1000LX SFP1006015.5.2.9Not supported on combo ports
Dual-speed Industrial Grade 100LX/1000LX SFP10060H15.5.2.9Not supported on combo ports

Summit X440 Switches: Optics Support

Table last updated 23 October 2017

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005215.1.1
LX Industrial Grade SFP10052H15.1.1
SX SFP1005115.1.1
SX Industrial Grade SFP10051H15.1.1
ZX SFP1005315.1.2
ZX Industrial Grade SFP10053H15.1.2
LX100 SFP1006415.1.1
1000BASE BX SFP (BX-D, BX-U)10056 / 1005715.1.1Used in -D & -U pairs
1000BASE BX Industrial Grade SFP10056H / 10057H15.2.2Used in -D & -U pairs
100BASE-FX SFP for fast Ethernet ports1006715.1.1
100BASE-LX10 SFP1006615.1.1
100BASE BX SFP (BX-D, BX-U)10058 / 1005915.1.1Used in -D & -U pairs
10/100/1000BASE-T copper SFP1006515.2.1Not supported on combo ports
10/100/1000BASE-T copper Industrial Grade SFP10070H15.2.1Not supported on combo ports
100LX/1000LX SFP1006015.2.2Not supported on combo ports
Dual-speed Industrial Grade 100LX/1000LX SFP10060H15.2.2Not supported on combo ports
SFP+
ER SFP+1030915.1.2
LR SFP+1030215.1.2
SR SFP+1030115.1.2
LRM SFP+1030315.1.2
ZR SFP+1031015.2.2
Tunable DWDM1032516.2
10Gb BX10-D / -U10GB-BX10-U
10GB-BX10-D
16.2
SFP+ direct-attach passive copper cable
1 meter1030415.1.2
3 meters1030515.1.2
5 meters1030615.1.2
10 meters1030715.1.2

Note: The XGM2-2sf ports are 10-Gb SFP+ ports and do not support 1-Gb optics (PD4-739782255).


ExtremeSwitching X440-G2 Switches: Optics Support

Table last updated 8 December 2017

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX Industrial Grade SFP10052H21.1.1
SX Industrial Grade SFP10051H21.1.1
ZX SFP10053H21.1.1
100LX/1000LX SFP10060
10060H
21.1.1
22.4.1
Supported only on 24 SFP ports on X440-G2-24x-10GE4 (16538)
Not supported on SFP combo ports
1Gb mode only on SFP/SFP+ uplink port
100FX SFP1006321.1.1Supported only on 24 SFP ports on X440-G2-24x-10GE4 (16538)
Not supported on SFP combo ports or SFP/SFP+ uplink ports
100BASE-FX SFP1006721.1.1Supported only on 24 SFP ports on X440-G2-24x-10GE4 (16538)
Not supported on SFP combo ports or SFP/SFP+ uplink ports
1000BASE-BX-D SFP10056H21.1.1Single fiber. Must be used with 10057H
1000BASE-BX-U SFP10057H21.1.1Single fiber. Must be used with 10056H
10/100/1000BASE-T copper Industrial Grade SFP10070H21.1.11G only on 1G uplink ports
Not supported on combo ports
1000BASE - BX10-D / -U 10 kmMGBIC-BX10-D
MGBIC-BX10-U
21.1.1Single fiber. Must be used in -D and -U pairs
1000BASE - BX40-D / -U 40 kmMGBIC-BX40-D
MGBIC-BX40-U
21.1.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE - BX120-D / -U 120 kmMGBIC-BX120-D
MGBIC-BX120-U
21.1.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
Industrial 1000Base-LX 1310nm MMF TransceiverI-MGBIC-LC0321.1.1
Industrial 1000Base-SX 850nm TransceiverI-MGBIC-GSX21.1.1
Industrial 1000Base-LX 1310nm SM TransceiverI-MGBIC-GLX21.1.1
SFP+
SR SFP+1030121.1.1
LR SFP+1030221.1.1
LRM SFP+1030321.1.1Supported only on combo ports
ER SFP+1030921.1.1
ZR SFP+10GB-ZR-SFPP21.1.1
10Gb SFP+ DWDM Tunable1032521.1.1
10Gb BX10-D / -U10GB-BX10-U
10GB-BX10-D
21.1.1Single fiber. Must be used in -D and -U pairs
10Gb BX40-D / -U10GB-BX40-U
10GB-BX40-D
21.1.1Single fiber. Must be used in -D and -U pairs
10GBASE-T SFP+1033821.1.3.2Populate every other SFP+ port in system, with a maximum of half the 10Gb SFP+ ports configured with 10GBASE-T transceivers. An adjacent SFP+ port should remain unused for every 10GBASE-T SFP+ installed.
SFP+ direct-attach passive copper cable
1 meter1030421.1.1
3 meters1030521.1.1
5 meters1030621.1.1
10 meters1030721.1.1Supported only on -48t and -48p models, 10Gb combo ports (51 and 52)
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP21.1.1
20 meters10GB-F20-SFPP21.1.1

Summit X450a Switches: Optics Support

Table last updated 23 October 2017

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005211.2.2.4
LX Industrial Grade SFP10052H11.2.2.4
SX SFP1005111.2.2.4
SX Industrial Grade SFP10051H11.2.2.4
ZX SFP1005311.2.2.4
LX100 SFP1006412.0.1.11
100FX SFP1006311.6.1.9
100LX/1000LX SFP (X450a-24x)1006011.6.1.9
Dual-speed Industrial Grade 100LX/1000LX SFP10060H11.6.1.9Not supported on combo ports
1000BX SFP10056 / 1005711.6.1.9Used in -D & -U pairs
10/100/1000BASE-T copper SFP1006512.0.2.25Not supported on combo ports
10/100/1000BASE-T copper Industrial Grade SFP10070H15.2.1Not supported on combo ports
SFP+ (XGM2-2sf option card required)
ER SFP+1030912.3.3
LR SFP+1030212.2.1
SR SFP+1030112.2.1
LRM SFP+1030312.5.2.2
ZR SFP+1031015.2.2
SFP+ direct-attach passive copper cable (XGM2-2sf option card required)
1 meter1030412.2.1
3 meters1030512.2.1
5 meters1030612.2.1
10 meters1030712.2.1

Summit X450e Switches: Optics Support

Table last updated 8 August 2016

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005211.6.1.9
LX Industrial Grade SFP10052H11.6.1.9
SX SFP1005111.6.1.9
SX Industrial Grade SFP10051H11.6.1.9
ZX SFP1005311.6.1.9
LX100 SFP1006412.0.1.11
1000BX SFP10056 / 1005711.6.1.9Used in -D & -U pairs
SFP+ (XGM2-2sf option card required)
ER SFP+1030912.3.3
LR SFP+1030212.2.1
SR SFP+1030112.2.1
LRM SFP+1030312.5.2.2
ZR SFP+1031015.2.2
SFP+ direct-attach passive copper cable (XGM2-2sf option card required)
1 meter1030412.2.1
3 meters1030512.2.1
5 meters1030612.2.1
10 meters1030712.2.1

Summit X450-G2 Switches: Optics Support

Table last updated 18 April 2018

Note: In addition to the minimum EXOS versions listed, this switch model is also supported on EXOS version 21.1.1 and later.

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX Industrial Grade SFP10052H16.1
SX Industrial Grade SFP10051H16.1
ZX Industrial Grade SFP10053H16.1
LX100 SFP1006416.1GE4 models only
10/100/1000BASE-T copper SFP1006516.1
1000BASE-BX-D SFP and BX-U SFP Industrial Temp10056H / 10057H16.1Used in-D & -U pairs
1000BASE - BX10-D / -U 10 kmMGBIC-BX10-D
MGBIC-BX10-U
22.4.1Single fiber. Must be used in -D and -U pairs
1000BASE - BX40-D / -U 40 kmMGBIC-BX40-D
MGBIC-BX40-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE - BX120-D / -U 120 kmMGBIC-BX120-D
MGBIC-BX120-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
10/100/1000BASE-T SFP Industrial Temp10070H16.11Gb speed only
SFP+
ER SFP+1030916.1
LR SFP+1030216.1
SR SFP+1030116.1
10G LRM SFP+1030316.1
ZR SFP+1031016.1
10Gb SFP+ DWDM Tunable1032521.1.1
10Gb BX10-D10GB-BX10-D21.1.1
10Gb BX10-U10GB-BX10-U21.1.1
10Gb BX40-D10GB-BX40-D16.1
10Gb BX40-U10GB-BX40-U16.1
10GBASE-T SFP+1033816.2.2.4-patch1
21.1.3.2
Populate every other SFP+ port in system, with a maximum of half the 10Gb SFP+ ports configured with 10GBASE-T transceivers. An adjacent SFP+ port should remain unused for every 10GBASE-T SFP+ installed.
SFP+ direct-attach passive copper cable
1 meter1030416.1
3 meters1030516.1
5 meters1030616.1
10 meters1030716.1
QSFP+ direct-attach active optical cable (SummitStack V84 ports only)
3 meters1033621.1.1SummitStack V84 only
5 meters1033721.1.1SummitStack V84 only
10 meters1031521.1.1SummitStack V84 only
20 meters1031621.1.1SummitStack V84 only
100 meters1031821.1.1SummitStack V84 only
QSFP+ direct-attach passive copper cable (SummitStack V84 ports only)
0.5 meters1031116.1SummitStack V84 only
1 meter1031216.1SummitStack V84 only
3 meters1031316.1SummitStack V84 only
5 meters1032316.1SummitStack V84 only
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP21.1.1
20 meters10GB-F20-SFPP21.1.1

Summit X460 Switches: Optics Support

Table last updated 23 October 2017

Pluggable Interface TypeSKU No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005212.5.1
LX Industrial Grade SFP10052H12.5.1
SX SFP1005112.5.1
SX Industrial Grade SFP10051H12.5.1
ZX SFP1005312.5.1
LX100 SFP1006412.5.1
100BASE-LX10 SFP1006612.5.1
100BX SFP10058 / 1005912.5.1Used in -D & -U pairs
100FX SFP1006311.6.1.9
1000BX SFP10056 / 1005712.5.1Used in -D & -U pairs
100BASE-FX SFP for fast Ethernet ports1006712.0.2.25
100LX/1000LX SFP1006012.5.1
Dual-speed Industrial Grade 100LX/1000LX SFP10060H12.5.1Not supported on combo ports
10/100/1000BASE-T copper SFP1006512.5.1
10/100/1000BASE-T copper Industrial Grade SFP10070H15.2.1
SFP+ (XGM3-2sf, XGM3S-2sf, or XGM3SB-4sf option card required)
ER SFP+1030912.5.1
LR SFP+1030212.5.1
SR SFP+1030112.5.1
LRM SFP+1030312.5.2.2
ZR SFP+1031015.2.2
10Gb BX10-D / -U10GB-BX10-U
10GB-BX10-D
16.2
SFP+ direct-attach passive copper cable (XGM3-2sf option card required)
1 meter1030412.2.1
3 meters1030512.2.1
5 meters1030612.2.1
10 meters1030712.2.1
QSFP+ (used for stacking with SummitStack-V80 option card)
SR4 QSFP+1031912.5.1
LR4 QSFP+1032015.2.1
Bidirectional MMF QSFP+1032916.21x40Gb mode only
QSFP+ direct-attach active optical cable (used for stacking with SummitStack-V80 option card)
3 meters1033616.1
5 meters1033716.1
10 meters1031512.2.1
20 meters1031615.1.1
100 meters1031812.2.1

Summit X460-G2 Switches: Optics Support

Table last updated 8 December 2017

Note: In addition to the minimum EXOS versions listed, this switch model is also supported on EXOS version 21.1.1 and later.

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005215.6.1.4
LX Industrial Grade SFP10052H15.6.1.4
SX SFP1005115.6.1.4
SX Industrial Grade SFP10051H15.6.1.4
ZX SFP1005315.6.1.4
ZX Industrial Grade SFP10053H15.6.1.4
100FX SFP1006315.6.1.4Not supported on combo ports
100LX/1000LX SFP10060
10060H
15.6.1.4
22.4.1
Not supported on combo ports
100BASE-FX SFP1006715.6.1.4
1000BASE-BX-D SFP and BX-U SFP Industrial Temp10056H / 10057H15.6.1.4Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE - BX10-D / -U 10 kmMGBIC-BX10-D
MGBIC-BX10-U
22.4.1Single fiber. Must be used in -D and -U pairs
1000BASE - BX40-D / -U 40 kmMGBIC-BX40-D
MGBIC-BX40-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE - BX120-D / -U 120 kmMGBIC-BX120-D
MGBIC-BX120-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
100BASE-BX-D SFP and BX-U SFP10058 / 1005915.6.1.4Single fiber. Used in -D & -U pairs
10/100/1000BASE-T SFP Industrial Temp10070H15.6.1.4Not supported on combo ports.
100BASE-LX101006615.6.1.4
SFP+
ER SFP+1030915.6.1.4
LR SFP+1030215.6.1.4
SR SFP+1030115.6.1.4
10G LRM SFP+ (only with VIM-2x)1030315.6.1.4only with VIM-2x
ZR SFP+1031015.6.1.4
10Gb SFP+ DWDM Tunable1032516.2
10Gb BX10-D / -U10GB-BX10-D
10GB-BX10-U
16.1.1.4
10Gb BX40-D / -U10GB-BX40-D
10GB-BX40-U
16.1.1.4
10GBASE-T SFP+1033816.2.2.4-patch1
21.1.3.2
Populate every other SFP+ port in system, with a maximum of half the 10Gb SFP+ ports configured with 10GBASE-T transceivers. An adjacent SFP+ port should remain unused for every 10GBASE-T SFP+ installed.
SFP+ direct-attach passive copper cable
1 meter1030415.6.1.4
3 meters1030515.6.1.4
5 meters (only with VIM-2x)1030615.6.1.4only with VIM-2x
10 meters (only with VIM-2x)1030715.6.1.4only with VIM-2x
QSFP+ (requires VIM-2q module)
SR4 QSFP+1031915.6.1.41x40Gb mode only
ESR4 QSFP+40GB-ESR4-QSFP22.4.11x40Gb mode only
LR4 QSFP+1032015.6.1.41x40Gb mode only
PSM LR4 QSFP+1032616.11x40Gb mode only
LM4 QSFP+1033416.21x40Gb mode only
ER4 QSFP+1033516.21x40Gb mode only
Bidirectional MMF QSFP+1032916.21x40Gb mode only
QSFP+ direct-attach active optical cable (requires VIM-2q module)
3 meters1033616.1
5 meters1033716.1
10 meters1031515.6.1.4
20 meters1031615.6.1.4
100 meters1031815.6.1.4
QSFP+ direct-attach passive copper cable (requires VIM-2q module)
0.5 meter1031115.6.1.4
1 meters1031215.6.1.4
3 meters1031315.6.1.4
5 meters1032315.6.1.4Not supported for SummitStack links
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP21.1.1
20 meters10GB-F20-SFPP21.1.1

Summit X480 Switches: Optics Support

Table last updated 23 October 2017

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005212.4.1
LX Industrial Grade SFP10052H12.4.1
SX SFP1005112.4.1
SX Industrial Grade SFP10051H12.4.1
ZX SFP1005312.4.1
LX100 SFP1006412.4.1
100BASE-FX SFP for fast Ethernet ports1006712.4.1
100BASE-LX10 SFP1006612.4.1
100BX SFP10058 / 1005912.4.1Used in -D & -U pairs
100LX/1000LX SFP1006012.4.1
Dual-speed Industrial Grade 100LX/1000LX SFP10060H12.4.1Not supported on combo ports
100FX SFP1006312.4.1
1000BX SFP10056 / 1005712.4.1Used in -D & -U pairs
10/100/1000BASE-T copper SFP1006512.4.1
10/100/1000BASE-T copper Industrial Grade SFP10070H15.2.1
QSFP+ (used for stacking with VIM2-SummitStack-V80 module)
SR4 QSFP+1031912.5.3
LR4 QSFP+1032015.2.1
QSFP+ (requires VIM3-40G4X)
SR4 QSFP+1031915.2.2
LR4 QSFP+1032015.2.1
PSM LR4 QSFP+1032616.1.1Can use with 10327 SMF fanout cable
LM4 QSFP+1033416.2
ER4 QSFP+1033516.2
Bidirectional MMF QSFP+1032916.21x40Gb mode only
QSFP+ direct-attach active optical cable (used for stacking with VIM2-SummitStack-V80 module)
3 meters1033616.1
5 meters1033716.1
10 meters1031512.5.3
20 meters1031615.1.1
100 meters1031812.5.3
QSFP+ direct-attach passive copper cable (used for stacking with VIM2-SummitStack-V80 module)
0.5 meters1031112.5.3
1 meter1031212.5.3
5 meters1032315.1.1
MPO Fanout Patch Cables
MTP/MPO to 4xLC SMF1032716.1.110m SMF fanout patch cord for use with PSM LR4 QSFP+ (10326)
MPO to 4xLC MMF9380014-5M16.1.15m MMF fanout patch cord for use with SR4 QSFP+ (10319)
QSFP+-to-SFP+ fan-out passive copper cable (requires VIM3-40G module)
3 meters1032115.1.1
5 meters1032215.1.1

ExtremeSwitching X590 Switches: Optics Support

Table last updated 6 September 2018

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
SX Industrial Grade SFP10051H22.6.1Supported for Extended Edge Switching
LX Industrial Grade SFP10052H22.6.1Supported for Extended Edge Switching
ZX SFP10053H22.6.1
Industrial 1000Base-LX 1310nm MMF TransceiverI-MGBIC-LC0322.6.1
1000BASE-BX-D / -U SFP 10km10056H / 10057H22.6.1Supported for Extended Edge Switching. Single fiber. 10056H & 10057H must be used in pairs. Industrial temperature.
10/100/1000BASE-T SFP10070H22.6.1Supported for Extended Edge Switching
1000BASE - BX40-D / -U 40 kmMGBIC-BX40-D
MGBIC-BX40-U
22.6.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE - BX120-D / -U 120 kmMGBIC-BX120-D
MGBIC-BX120-U
22.6.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE-T RJ45 SFPMGBIC-0222.6.1
SFP+
SR SFP+1030122.6.1Supported for Extended Edge Switching
LR SFP+1030222.6.1Supported for Extended Edge Switching
LRM SFP+1030322.6.1
ER SFP+1030922.6.1
ZR SFP+1031022.6.1
10Gb SFP+ DWDM Tunable1032522.6.1
10Gb BX10-D -U10GB-BX10-D
10GB-BX10-U
22.6.1Supported for Extended Edge Switching
10Gb BX40-D -U10GB-BX40-D
10GB-BX40-U
22.6.1
10GBASE-T SFP+1033822.6.1Supported for X590-24t-1q-2c: populate every other SFP+ port in system, with a maximum of half the 10Gb SFP+ ports configured with 10GBASE-T transceivers. An adjacent SFP+ port should remain unused for every 10GBASE-T SFP+ installed.
Supported for Extended Edge Switching.
QSFP+
SR4 QSFP+1031922.6.1
ESR4 QSFP+40GB-ESR4-QSFP22.6.1
LR4 QSFP+1032022.6.1
PSM LR4 QSFP+1032622.6.1
LM4 QSFP+1033422.6.1
ER4 QSFP+1033522.6.1
Bidirectional MMF QSFP+1032922.6.1
QSFP28Note: Do not use for stacking. Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X590 stacking ports.
100Gb SR4 QSFP28 MMF1040122.6.1
100Gb LR4 QSFP28 10 km1040322.6.1
100Gb CWDM4 QSFP28 SMF 2km1040422.6.1
100Gb PSM4 QSFP28 SMF, 2km1040522.6.1MPO parallel fiber, SMF
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP22.6.1Supported for Extended Edge Switching
20 meters10GB-F20-SFPP22.6.1Supported for Extended Edge Switching
SFP+ direct-attach passive copper cable
1 meter1030422.6.1Supported for Extended Edge Switching
3 meters1030522.6.1Supported for Extended Edge Switching
5 meters1030622.6.1Supported for Extended Edge Switching
10 meters1030722.6.1
QSFP+ direct-attach active optical cable
3 meters1033622.6.1
5 meters1033722.6.1
10 meters1031522.6.1
20 meters1031622.6.1
100 meters1031822.6.1
QSFP+-to-4xSFP+ fan-out copper cable
3 meters1032122.6.1
5 meters1032222.6.1
QSFP+ direct-attach passive copper cable
0.5 meter1031122.6.1
1 meter1031222.6.1
3 meters1031322.6.1
5 meters1032322.6.1
Multiple-format cables and adapters
10 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F10-QSFP22.6.1
20 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F20-QSFP22.6.1
QSFP+ to SFP+ adapterQSFP-SFPP-ADPT22.6.1Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1.
AOC QSFP28 active optical cableNote: Do not use for stacking. Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X590 stacking ports.
5 meters1043422.6.1
7 meters1043522.6.1
10 meters1043622.6.1
20 meters1043722.6.1
AOC QSFP28 x 4 SFP28 (4x25Gb) active optical breakout cable
5 meters1044122.6.1
7 meters1044222.6.1
10 meters1044322.6.1
20 meters1044422.6.1
DAC QSFP28 passive copper cableNote: Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X590 stacking ports.
0.5 meter1041022.6.1
1 meter1041122.6.1
3 meters1041322.6.1
5 meters1041422.6.1
DAC QSFP28-4xSFP28 passive copper breakout cable
1 meter1042122.6.1
3 meters1042322.6.1
5 meters1042422.6.1Can also be used for 40 Gb to 4 x 10 Gb speed breakout
DAC QSFP28-2xSFP28 (2x50Gb) passive copper breakout cable
1 meter1042622.6.1
3 meters1042822.6.1
AOC QSFP28-2xSFP28 (2x50Gb) active optical breakout cable
5 meters1044622.6.1
7 meters1044722.6.1
10 meters1044822.6.1
20 meters1044922.6.1

ExtremeSwitching X620 Switches: Optics Support

Table last updated 8 December 2017

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX Industrial Grade SFP10052H21.1.1
SX Industrial Grade SFP10051H21.1.1
ZX SFP10053H21.1.1
100BASE-LX10 SFP1006621.1.1
100FX SFP1006321.1.1Not supported on combo ports
100LX/1000LX SFP1006021.1.1Not supported on combo ports
1000BASE - BX10-D / -U10056H
10057H
21.1.1Single fiber
10056H & 10057H must be used in pairs
1000BASE - BX10-D / -U 10 kmMGBIC-BX10-D
MGBIC-BX10-U
22.4.1Single fiber
Must be used in -D and -U pairs
1000BASE - BX40-D / -UMGBIC-BX40-D
MGBIC-BX40-U
21.1.1Single fiber
Must be used in -D and -U pairs
Industrial temperature
1000BASE - BX120-D / -UMGBIC-BX120-D
MGBIC-BX120-U
21.1.1Single fiber
Must be used in -D and -U pairs
Industrial temperature
10/100/1000BASE-T copper Industrial Grade SFP10070H21.1.11 Gb speed only
Not supported in combo ports
SFP+
SR SFP+1030121.1.1
LR SFP+1030221.1.1
LRM SFP+1030321.1.1Supported only on X620-16t and X620-16p combo ports (13-16)
ER SFP+1030921.1.1
ZR SFP+1031021.1.1
10Gb SFP+ DWDM Tunable1032521.1.1
10Gb BX10-D / -U10GB-BX10-D
10GB-BX10-U
21.1.1
10Gb BX40-D / -U10GB-BX40-D
10GB-BX40-U
21.1.1
10GBASE-T SFP+1033821.1.3.2Populate every other SFP+ port in system, with a maximum of half the 10Gb SFP+ ports configured with 10GBASE-T transceivers. An adjacent SFP+ port should remain unused for every 10GBASE-T SFP+ installed.
SFP+ direct-attach passive copper cable
1 meter1030421.1.1
3 meters1030521.1.1
5 meters1030621.1.1
10 meters1030721.1.1Supported only on X620-16t and X620-16p combo ports (13-16)
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP21.1.1
20 meters10GB-F20-SFPP21.1.1

Summit X650 Switches: Optics Support

Table last updated 20 March 2017

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
BX SFP10056 / 1005712.2.1Used in -D & -U pairs
LX SFP1005212.2.1
LX Industrial Grade SFP10052H12.2.1
SX SFP1005112.2.1
SX Industrial Grade SFP10051H12.2.1
ZX SFP1005312.2.1
LX100 SFP1006412.2.1
10/100/1000BASE-T copper SFP—1000 speed support only1006512.3.3
10/100/1000BASE-T copper Industrial Grade SFP—1000 speed support only10070H15.2.1
SFP+
ER SFP+1030912.2.2
LR SFP+1030212.2.2
SR SFP+1030112.3.3
ZR SFP+ (VIM1 module ports 1 through 22)1031015.2.2
LRM SFP+1030312.2.2
SFP+ direct-attach passive copper cable
1 meter1030412.2.1
3 meters1030512.2.1
5 meters1030612.2.1
10 meters1030712.2.1
QSFP+ (requires VIM3-40G module)
SR QSFP+1031912.5.3
LR4 QSFP+1032015.2.1
QSFP+ direct-attach active optical cable (used for stacking with VIM2-SummitStack-V80 module)
10 meters1031512.5.3
20 meters1031615.1.1
100 meters1031812.5.3
QSFP+ direct-attach passive copper cable (used for stacking with VIM2-SummitStack-V80 module)
0.5 meters1031112.5.3
1 meter1031212.5.3
5 meters1032315.1.1
QSFP+-to-SFP+ fan-out passive copper cable (requires VIM3-40G module)
3 meters1032115.1.1
5 meters1032215.1.1

Summit X670 Switches: Optics Support

Table last updated 8 August 2016

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005212.6.1
LX Industrial Grade SFP10052H12.6.1
SX SFP1005112.6.1
SX Industrial Grade SFP10051H12.6.1
ZX SFP1005312.6.1
ZX Industrial Grade SFP10053H12.6.1
LX100 SFP1006412.6.1
10/100/1000BASE-T copper SFP)1006512.6.1Gigabit speed only
10/100/1000BASE-T copper Industrial Grade SFP10070H15.2.1Gigabit speed only
SFP+
ER SFP+1030912.6.1
LR SFP+1030212.6.1
SR SFP+1030112.6.1
ZR SFP+1031015.2.2
Tunable DWDM1032516.2
10Gb BX10-D / -U10GB-BX10-D
10GB-BX10-U
16.2
SFP+ direct-attach passive copper cable
1 meter1030412.6.1
3 meters1030512.6.1
5 meters1030612.6.1
QSFP+ (requires VIM4-40G4X module)
LM4 QSFP+1033416.2
ER4 QSFP+1033516.2
Bidirectional MMF QSFP+1032916.21x40Gb mode only

Summit X670V Switches: Optics Support

Table last updated 7 October 2016

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005212.6.1
LX Industrial Grade SFP10052H12.6.1
SX SFP1005112.6.1
SX Industrial Grade SFP10051H12.6.1
ZX SFP1005312.6.1
ZX Industrial Grade SFP10053H12.6.1
LX100 SFP1006412.6.1
10/100/1000BASE-T copper Industrial Grade SFP10070H15.2.1Gigabit speed only
SFP+
ER SFP+1030912.6.1
LR SFP+1030212.6.1
SR SFP+1030112.6.1
ZR SFP+1031015.2.2
10G LRM SFP+1030315.3.2X670V-48x only
Tunable DWDM1032516.2
10Gb BX10-D / -U10GB-BX10-D
10GB-BX10-U
16.2
SFP+ direct-attach passive copper cable
1 meter1030412.6.1
3 meters1030512.6.1
5 meters1030612.6.1
10 meters1030712.6.1
QSFP+ (requires VIM4-40G4X module)
SR4 QSFP+1031912.6.1Can use with 9380014-5M for 10Gb fanout
LR4 QSFP+1032015.2.1
PSM LR4 QSFP+1032616.1.1Can use with 10327 SMF fanout cable
LM4 QSFP+1033416.2
ER4 QSFP+1033516.2
Bidirectional MMF QSFP+1032916.21x40Gb mode only
Fanout Cables (requires VIM4-40G module)
MTP/MPO to 4xLC SMF1032716.1.110m SMF fanout patch cord for use with PSM LR4 QSFP+ (10326)
MPO to 4xLC MMF9380014-5M16.1.15m MMF fanout patch cord for use with SR4 QSFP+ (10319)
QSFP+ direct-attach active optical cable (requires VIM4-40G module)
3 meters1033615.1.1
5 meters1033716.1
10 meters1031512.6.1
20 meters1031615.1.1
100 meters1031812.6.1
QSFP+-to-SFP+ direct-attach fan-out passive copper cable (requires VIM4-40G module)
1 meter1020215.1.1
2 meters1020315.1.1
3 meters1032115.1.1
5 meters1032215.1.1
QSFP+ direct-attach passive copper cable (requires VIM4-40G module)
0.5 meter1031112.6.1
1 meter1031212.6.1
5 meter1032315.1.1

Summit X670-G2 Switches: Optics Support

Table last updated 7 September 2018

Note: In addition to the minimum EXOS versions listed, this switch model is also supported on EXOS version 21.1.1 and later.

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
SX SFP1005115.6.1.4
SX Industrial Grade SFP10051H15.6.1.4Supported for Extended Edge Switching - EXOS 22.5 or later
LX SFP1005215.6.1.4
LX Industrial Grade SFP10052H15.6.1.4Supported for Extended Edge Switching - EXOS 22.5 or later
ZX SFP1005315.6.1.4
ZX Industrial Grade SFP10053H15.6.1.4
1000BASE-BX-D / -U SFP 10km10056H / 10057H22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature. Supported for Extended Edge Switching - EXOS 22.5 or later.
1000BASE - BX10-D / -U 10 kmMGBIC-BX10-D
MGBIC-BX10-U
22.4.1Single fiber. Must be used in -D and -U pairs
1000BASE - BX40-D / -U 40 kmMGBIC-BX40-D
MGBIC-BX40-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE - BX120-D / -U 120 kmMGBIC-BX120-D
MGBIC-BX120-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
10/100/1000BASE-T SFP Industrial Temp10070H15.6.1.41Gb speed only. Supported for Extended Edge Switching - EXOS 22.5 or later.
SFP+
SR SFP+1030115.6.1.4Supported for Extended Edge Switching - EXOS 22.5 or later
LR SFP+1030215.6.1.4Supported for Extended Edge Switching - EXOS 22.5 or later
ER SFP+1030915.6.1.4
ZR SFP+1031015.6.1.4
10Gb SFP+ DWDM Tunable1032516.2X670-G2-48x-4q only
10Gb BX10-D / -U10GB-BX10-D
10GB-BX10-U
21.1.1Supported for Extended Edge Switching - EXOS 22.5 or later
10GBASE-T SFP+1033816.2.2.4-patch1
21.1.3.2
Populate every other SFP+ port in system, with a maximum of half the 10Gb SFP+ ports configured with 10GBASE-T transceivers. An adjacent SFP+ port should remain unused for every 10GBASE-T SFP+ installed. Supported for Extended Edge Switching - EXOS 22.5 or later.
SFP+ direct-attach passive copper cable
1 meter1030415.6.1.4Supported for Extended Edge Switching - EXOS 22.5 or later
3 meters1030515.6.1.4Supported for Extended Edge Switching - EXOS 22.5 or later
5 meters1030615.6.1.4Supported for Extended Edge Switching - EXOS 22.5 or later. Not supported for SummitStack links.
QSFP+ (X670-G2-48x-4q only)
SR4 QSFP+1031915.6.1.4Can use with 9380014-5M or 10332 for 10Gb fan-out
ESR4 QSFP+40GB-ESR4-QSFP22.4.1Can use with 9380014-5M or 10332 for 10Gb fan-out
LR4 QSFP+1032015.6.1.4
PSM LR4 QSFP+1032616.1.1Can use with 10327 SMF fanout cable
LM4 QSFP+1033416.2
ER4 QSFP+1033516.2
Bidirectional MMF QSFP+1032916.21x40Gb mode only
Multiple-format adapters
QSFP+ to SFP+ adapterQSFP-SFPP-ADPT22.4.1Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
X670-G2-48x-4q 40Gb ports only
10338 not supported
QSFP28 to SFP28 adapter1050622.5Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
QSFP+ direct-attach active optical cable (X670-G2-48x-4q only)
3 meters1033616.1
5 meters1033716.1
10 meters1031515.6.1.4
20 meters1031615.6.1.4
100 meters1031815.6.1.4
QSFP+-to-SFP+ direct-attach fan-out passive copper cable (X670-G2-48x-4q only)
1 meter1020215.6.1.4
2 meters1020315.6.1.4
3 meters1032115.6.1.4
Fanout Patch Cables (X670-G2-48x-4q only)
MTP/MPO to 4xLC SMF10327NA10m SMF fan-out patch cord for use with PSM LR4 QSFP+ (10326) or QSFP28 PSM4 (10405)
MPO to 4xLC MMF10332 (OM4)
9380014-5M (OM3)
NA5m MMF fan-out patch cord for use with SR4 QSFP+ (10319, ESR4 QSFP+ (40GB-ESR4-QSFP) or SR4 QSFP28 (10401)
AOC QSFP+ to SFP+ cables
10 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F10-QSFP22.4.1
20 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F20-QSFP22.4.1
QSFP+ direct-attach passive copper cable (X670-G2-48x-4q only)
0.5 meter1031115.6.1.4
1 meter1031215.6.1.4
3 meters1031315.6.1.4
5 meters1032315.6.1.4Not supported for SummitStack links
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP21.1.1Supported for Extended Edge Switching - EXOS 22.5 or later
20 meters10GB-F20-SFPP21.1.1Supported for Extended Edge Switching - EXOS 22.5 or later

ExtremeSwitching X690 Switches: Optics Support

Table last updated 7 September 2018

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
SX Industrial Grade SFP10051H22.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
LX Industrial Grade SFP10052H22.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
ZX SFP10053H22.3.1
Industrial 1000Base-LX 1310nm MMF TransceiverI-MGBIC-LC0322.3.1
1000BASE-BX-D / -U SFP 10km10056H / 10057H22.4.1Single fiber. 10056H & 10057H must be used in pairs. Industrial temperature.
Supported for Extended Edge Switching - EXOS 22.5 or later.
1000BASE - BX10-D / -U 10 kmMGBIC-BX10-D
MGBIC-BX10-U
22.4.1Single fiber. Must be used in -D and -U pairs
1000BASE - BX40-D / -U 40 kmMGBIC-BX40-D
MGBIC-BX40-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE - BX120-D / -U 120 kmMGBIC-BX120-D
MGBIC-BX120-U
22.4.1Single fiber. Must be used in -D and -U pairs. Industrial temperature.
1000BASE-T RJ45 SFPMGBIC-0222.3.1.4-patch3-21Gb speed only (10070H is not compatible with X690)
SFP+
SR SFP+1030122.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
LR SFP+1030222.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
ER SFP+1030922.3.1
10Gb SFP+ DWDM Tunable1032522.3.1
10Gb BX10-U10GB-BX10-U22.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
10Gb BX10-D10GB-BX10-D22.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
10Gb BX40-U10GB-BX40-U22.3.1
10Gb BX40-D10GB-BX40-D22.3.1
10GBASE-T SFP+1033822.3.1Populate every other SFP+ port in system, with a maximum of half the 10Gb SFP+ ports configured with 10GBASE-T transceivers. An adjacent SFP+ port should remain unused for every 10GBASE-T SFP+ installed.
Supported for Extended Edge Switching - EXOS 22.5 or later.
SFP28
25G SFP28 SR 850nm1050122.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
25G SFP28 SR Lite-FEC 850nm1050222.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
25G SFP28 ESR1050322.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
25G SFP28 LR 10 km 1310nm1050422.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
QSFP+
SR4 QSFP+1031922.3.1Can use with 9380014-5M or 10332 for 10Gb fan-out
ESR4 QSFP+40GB-ESR4-QSFP22.4.1Can use with 9380014-5M or 10332 for 10Gb fan-out
LR4 QSFP+1032022.3.1
PSM LR4 QSFP+1032622.3.1Can use with 10327 SMF fan-out cable
LM4 QSFP+1033422.3.1
ER4 QSFP+1033522.3.1
Bidirectional MMF QSFP+1032922.3.11x40Gb mode only
QSFP28Note: Do not use for stacking. Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X690 stacking ports.
100Gb SR4 QSFP28 MMF1040122.3.1Can use with 10332 for 25Gb fan-out
100Gb LR4 QSFP28 10 km1040322.3.1
100Gb CWDM4 QSFP28 SMF 2km1040422.3.1
100Gb PSM4 QSFP28 SMF, 2km1040522.3.1MPO parallel fiber, SMF
Can use with 10327 SMF cable for 4x25Gb fanout
100G QSFP28 SWDM1040622.5
QSFP28 CWDM-Lite OCP1045022.5
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP22.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
20 meters10GB-F20-SFPP22.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
SFP+ direct-attach passive copper cable
1 meter1030422.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
3 meters1030522.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
5 meters1030622.3.1Supported for Extended Edge Switching - EXOS 22.5 or later
10 meters1030722.3.1Ports 1-8 only
SFP28 direct-attach passive copper cable
1 meter1052022.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
3 meters1052122.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
5 meters1052222.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
SFP28-SFP28 25Gb direct-attach active optical cable
10 meters1053022.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
20 meters1053122.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
QSFP+ direct-attach active optical cable
3 meters1033622.3.1
5 meters1033722.3.1
10 meters1031522.3.1
20 meters1031622.3.1
100 meters1031822.3.1
QSFP+-to-4xSFP+ fan-out copper cable
1 meter1020222.3.1
2 meters1020322.3.1
3 meters1032122.3.1
5 meters1032222.3.1
QSFP+ direct-attach passive copper cable
0.5 meter1031122.3.1
1 meter1031222.3.1
3 meters1031322.3.1
5 meters1032322.3.1
Multiple-format cables and adapters
10 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F10-QSFP22.3.1
20 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F20-QSFP22.3.1
QSFP+ to SFP+ adapterQSFP-SFPP-ADPT22.3.1Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
10338 not supported
QSFP28 to SFP28 adapter1050622.5Supported in QSFP28 100Gb ports with SFP28 25Gb transceivers
Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
AOC QSFP28 active optical cableNote: Do not use for stacking. Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X690 stacking ports.
5 meters1043422.3.1
7 meters1043522.3.1
10 meters1043622.3.1
20 meters1043722.3.1
AOC QSFP28 x 4 SFP28 (4x25Gb) active optical breakout cable
5 meters1044122.3.1
7 meters1044222.3.1
10 meters1044322.3.1
20 meters1044422.3.1
DAC QSFP28 passive copper cableNote: Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X690 stacking ports.
0.5 meter1041022.3.1
1 meter1041122.3.1
3 meters1041322.3.1
5 meters1041422.3.1
DAC QSFP28-4xSFP28 passive copper breakout cable
1 meter1042122.3.1
3 meters1042322.3.1
5 meters1042422.3.1
DAC QSFP28-2xSFP28 (2x50Gb) passive copper breakout cable
1 meter1042622.3.1
3 meters1042822.3.1
5 meters1042922.3.1
AOC QSFP28-2xSFP28 (2x50Gb) active optic breakout cable
5 meters1044622.5
7 meters1044722.5
10 meters1044822.5
20 meters1044922.5
Fan-out patch cable
MTP/MPO to 4xLC SMF10327NA10m SMF fan-out patch cord for use with PSM LR4 QSFP+ (10326) or QSFP28 PSM4 (10405)
MPO to 4xLC MMF10332 (OM4)
9380014-5M (OM3)
NA5m MMF fan-out patch cord for use with SR4 QSFP+ (10319, ESR4 QSFP+ (40GB-ESR4-QSFP) or SR4 QSFP28 (10401)

Summit X770 Switches: Optics Support

Table last updated 31 May 2018

Note: In addition to the minimum EXOS versions listed, this switch model is also supported on EXOS version 21.1.1 and later.

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP+
SR SFP+1030116.1.2Used with QSFP-SFPP-ADPT
LR SFP+1030216.1.2Used with QSFP-SFPP-ADPT
ER SFP+1030916.1.2Used with QSFP-SFPP-ADPT
ZR SFP+1031016.1.2Used with QSFP-SFPP-ADPT
10Gb BX10-D / -U10GB-BX10-D
10GB-BX10-U
21.1.1Used with QSFP-SFPP-ADPT
QSFP+
SR4 QSFP+1031915.4.1
ESR4 QSFP+40GB-ESR4-QSFP22.4.1Can use with 9380014-5M or 10332 for 10Gb fan-out
LR4 QSFP+1032015.4.1
PSM LR4 QSFP+1032616.1.1Can use with 10327 SMF fanout cable
LM4 QSFP+1033416.2
ER4 QSFP+1033516.2
Bidirectional MMF QSFP+1032916.21x40Gb mode only
Multiple-format adapters
QSFP+ to SFP+ adapterQSFP-SFPP-ADPT16.1.2Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
10338 not supported
QSFP28 to SFP28 adapter1050622.5Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP16.1.2Used with QSFP-SFPP-ADPT
20 meters10GB-F20-SFPP16.1.2Used with QSFP-SFPP-ADPT
QSFP+ direct-attach active optical cable
3 meters1033616.1
5 meters1033721.1.1
10 meters1031515.4.1
20 meters1031615.4.1
100 meters1031815.4.1
QSFP+-to-SFP+ direct-attach fan-out passive copper cable
1 meter (26 AWG)1020215.4.1
2 meters (26 AWG)1020315.4.1
3 meters1032115.4.1
Fanout Cables
MTP/MPO to 4xLC SMF10327NA10m SMF fanout patch cord for use with PSM LR4 QSFP+ (10326)
MPO to 4xLC MMF10332 (OM4)
9380014-5M (OM3)
NA5m MMF fan-out patch cord for use with SR4 QSFP+ (10319, ESR4 QSFP+ (40GB-ESR4-QSFP) or SR4 QSFP28 (10401)
QSFP+ direct-attach passive copper cable
0.5 meter1031115.4.1
1 meter1031215.4.1
3 meters (26 AWG)10313A15.4.1
3 meters1031315.4.1
AOC QSFP+ to SFP+ cables
10 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F10-QSFP22.4.1
20 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F20-QSFP22.4.1

ExtremeSwitching X870 Switches: Optics Support

Table last updated 6 September 2018

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP+
SR SFP+1030122.4.1Used with QSFP-SFPP-ADPT
LR SFP+1030222.4.1Used with QSFP-SFPP-ADPT
ER SFP+1030922.4.1Used with QSFP-SFPP-ADPT
ZR SFP+1031022.4.1Used with QSFP-SFPP-ADPT
10Gb BX10-D / -U10GB-BX10-D
10GB-BX10-U
22.4.1Used with QSFP-SFPP-ADPT
QSFP+
SR4 QSFP+1031922.2.1.5Can use with 9380014-5M or 10332 for 10Gb fan-out
ESR4 QSFP+40GB-ESR4-QSFP22.4.1Can use with 9380014-5M or 10332 for 10Gb fan-out
LR4 QSFP+1032022.2.1.5
PSM LR4 QSFP+1032622.2.1.5Can use with 10327 SMF fan-out cable for 4x10Gb
LM4 QSFP+1033422.2.1.5
ER4 QSFP+1033522.2.1.5
Bidirectional MMF QSFP+1032922.2.1.51x40Gb mode only
SFP28
25G SFP28 SR 850nm1050122.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
25G SFP28 SR Lite-FEC 850nm1050222.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
25G SFP28 ESR1050322.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
25G SFP28 LR 10 km 1310nm1050422.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
QSFP28Note: Do not use for stacking. Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X870 stacking ports.
100Gb SR4 QSFP28 MMF1040122.2.1.5
100Gb LR4 QSFP28 10 km1040322.2.1.5
100Gb CWDM4 QSFP28 SMF 2km1040422.2.1.5
100Gb PSM4 QSFP28 SMF, 2km1040522.2.1.5MPO parallel fiber, SMF
Can use with 10327 SMF fan-out cable
100G QSFP28 SWDM1040622.5
QSFP28 CWDM-Lite OCP1045022.5
SFP28 direct-attach passive copper cable
1 meter1052022.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
3 meters1052122.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
5 meters1052222.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
SFP28-SFP28 25Gb direct-attach active optical cable
10 meters1053022.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
20 meters1053122.5Requires QSFP to SFP28 adapter (10506) for QSFP28 ports
QSFP+ direct-attach active optical cable
3 meters1033622.2.1.5
5 meters1033722.2.1.5
10 meters1031522.2.1.5
20 meters1031622.2.1.5
100 meters1031822.2.1.5
QSFP+-to-4xSFP+ fan-out copper cable
1 meter1020222.2.1.5
2 meters1020322.2.1.5
3 meters1032122.2.1.5
Fan-out patch cable
MTP/MPO to 4xLC SMF10327NA10m SMF fan-out patch cord for use with PSM LR4 QSFP+ (10326) or QSFP28 PSM4 (10405)
MPO to 4xLC MMF10332 (OM4)
9380014-5M (OM3)
NA5m MMF fan-out patch cord for use with SR4 QSFP+ (10319, ESR4 QSFP+ (40GB-ESR4-QSFP) or SR4 QSFP28 (10401)
QSFP+ direct-attach passive copper cable
0.5 meter1031122.2.1.5
1 meter1031222.2.1.5
3 meters1031322.2.1.5
5 meters1032322.2.1.5Not supported for SummitStack links
Multiple-format cables and adapters
10 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F10-QSFP22.2.1.5
20 meters 4xSFP+ to QSFP+
active optical AOC fan-out
10GB-4-F20-QSFP22.2.1.5
QSFP+ to SFP+ adapterQSFP-SFPP-ADPT22.4.1Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
10338 not supported
QSFP28 to SFP28 adapter1050622.5Supported in QSFP28 100Gb ports with SFP28 25Gb transceivers
Supported in QSFP+ 40Gb ports for SFP+ 10Gb transceivers
In multi-lane ports, always uses data lane 1
AOC QSFP28 active optical cableNote: Do not use for stacking. Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X870 stacking ports.
5 meters1043422.2.1.5
7 meters1043522.2.1.5
10 meters1043622.2.1.5
20 meters1043722.2.1.5
AOC QSFP28 x 4 SFP28 (4x25Gb) active optical breakout cable
5 meters1044122.2.1.5
7 meters1044222.2.1.5
10 meters1044322.2.1.5
20 meters1044422.2.1.5
DAC QSFP28 passive copper cableNote: Only QSFP28 direct-attach passive copper cable, at lengths up to 5 meters, can be used in X870 stacking ports.
0.5 meter1041022.2.1.5
1 meter1041122.2.1.5
3 meters1041322.2.1.5
5 meters1041422.2.1.5
DAC QSFP28-4xSFP28 passive copper breakout cable
1 meter1042122.2.1.5
3 meters1042322.2.1.5
5 meters1042422.2.1.5
DAC QSFP28-2xSFP28 (2x50Gb) passive copper breakout cable
1 meter1042622.2.1.5
3 meters1042822.2.1.5
5 meters1042922.5
AOC QSFP28-2xSFP28 (2x50Gb) active optic breakout cable
5 meters1044622.5
7 meters1044722.5
10 meters1044822.5
20 meters1044922.5

ExtremeSwitching V400 Port Extenders: Optics Support

Table last updated 26 July 2018

Pluggable Interface TypePart No.Minimum ExtremeXOS Software VersionComments
SFP
SX Industrial Grade SFP10051H22.5
LX Industrial Grade SFP10052H22.5
1000BASE-BX-D SFP10056H22.5Single fiber. Must be used with 10057H
1000BASE-BX-U SFP10057H22.5Single fiber. Must be used with 10056H
10/100/1000BASE-T copper Industrial Grade SFP10070H22.5Supported only for X670-G2 controlling bridge (not for X590 or X690)
SFP+
SR SFP+1030122.5
LR SFP+1030222.5
10GBASE-T SFP+1033822.5
10Gb BX10-D / -U10GB-BX10-U
10GB-BX10-D
22.5Single fiber. Must be used in -D and -U pairs
SFP+ direct-attach passive copper cable
1 meter1030422.5
3 meters1030522.5
5 meters1030622.5
SFP+ direct-attach active optical cable
10 meters10GB-F10-SFPP22.5
20 meters10GB-F20-SFPP22.5

E4G-Series Routers: Optics Support

Table last updated 23 October 2017

Pluggable Interface TypeSKU No.Minimum ExtremeXOS Software VersionComments
SFP
LX SFP1005215.1.1
LX Industrial Grade SFP10052H15.1.1
SX SFP1005115.1.1
SX Industrial Grade SFP10051H15.1.1
ZX SFP1005315.1.1
LX100 SFP1006415.1.1
100BASE-LX10 SFP1006615.1.1
100BX SFP10058 / 1005915.1.1Used in -D & -U pairs
100FX SFP1006315.1.1Not supported on E4G-400 combo ports
1000BX SFP10056 / 1005715.1.1Used in -D & -U pairs
100BASE-FX SFP for fast Ethernet ports1006715.1.1
100LX/1000LX SFP1006015.1.1Not supported on E4G-400 combo ports
Dual-speed Industrial Grade 100LX/1000LX SFP10060H15.1.1Not supported on E4G-400 combo ports
10/100/1000BASE-T copper SFP1006515.1.1Not supported on E4G-400 combo ports
10/100/1000BASE-T copper Industrial Grade10070H15.2.1Not supported on E4G-400 combo ports
SFP+ (XGM3S-2sf or XGM3SB-4sf option card required)
ER SFP+1030915.1.1
LR SFP+1030215.1.1
SR SFP+1030115.1.1
LRM SFP+1030315.1.1
ZR SFP+1031015.2.2
SFP+ direct-attach passive copper cable (XGM3S-2sf or XGM3SB-4sf option card required)
1 meter1030415.1.1
3 meters1030515.1.1
5 meters1030615.1.1
10 meters1030715.1.1

We value your feedback about Extreme Networks documentation. Use our online feedback form to post a comment or suggestion about this information.