Open, Extensible Switching Platform Features Network Visibility and Automation Innovations
Let Extreme VDX 6740 switches help you build a smart virtualization strategy by meeting the demands of today’s applications with easy scalability and automated management. These Top of Rack (ToR) switches support 1/10/40 GbE ports—enabling the efficiency and flexibility you need to support cloud computing, virtualization, mobility, and consolidation.
Click to talk to a network expert
Join the Conversation
Learn how you can create possibilities and enable virtualization with @OpenStack! https://t.co/nIWlfuKTEs https://t.co/pPtPFvBRM9
51 minutes ago
Stop by booth #519 at @Supercomputing Conference for your chance to win a microcontroller and see our demos! #SC17… https://t.co/q4fuoQC6Bp
14 hours ago
Architectural Flexibility
- Select your architecture of choice to address your network needs and protect your investments
- Save time and resources with elastic, self-forming, and self-healing fabrics
- Deliver optimal low-latency support for east-west traffic with per-packet load balancing at Layers 1, 2, and 3
- Deliver advanced storage networking with improved performance, management, security, span of control and connectivity for FCoE, iSCSI and NAS
High-capacity ports and buffers
- 1000BASE-T, 10G BASE-T ports, 40 GbE uplink ports, and 24 MB deep buffers
- Leverage existing wiring infrastructure while moving to a higher bandwidth, from 1000BASE-T to 10GBASE-T
- Aggregate high bandwidth traffic
- Industry-leading buffering and load balanced multipathing handles traffic increases with distribution across ports
Cloud-Optimized Automation
- Scale out the fabric without adding complexity
- Support open SDN architectures
- Use common industry automation tools such as Puppet, Ansible, VMware vRealize plug-ins, and YANG model-based REST and Netconf APIs
- Orchestrate and control your cloud through OpenStack and OpenDaylight-based SDN Controller support
- Provide a choice of multitenant solutions using Virtual Fabrics for tenant isolation within a data center and across data centers
Click to talk to a network expert
Join the Conversation
Learn how you can create possibilities and enable virtualization with @OpenStack! https://t.co/nIWlfuKTEs https://t.co/pPtPFvBRM9
51 minutes ago
Stop by booth #519 at @Supercomputing Conference for your chance to win a microcontroller and see our demos! #SC17… https://t.co/q4fuoQC6Bp
14 hours ago
High Performance Plus Low Latency
Support virtualized data centers, reduce network congestion, and meet today’s demanding application performance requirements. The Extreme VDX 6740 offers wire speed and non-blocking packet forwarding to meet the capacity requirements of 1/10/40GbE servers and storage.
Simplicity and Automation
Streamline configuration and management, maximize efficiency and improve automation in highly virtualized data centers. We build in data center fabric innovations like scalable multitenancy, unification of virtual and physical environments, support for layer 3 gateways, automated storage traffic prioritization, and support for open cloud orchestration.
Efficiency and Resiliency
Create a more efficient, resilient and flexible network that adapts to changing business conditions and traffic patterns. Extreme data center fabric technologyhelps your organization maximize network bandwidth and allows for immediate discovery and recovery across all networking nodes
| VDX 6740 | VDX 6740T | VDX 6740T-1G | |
| Form Factor | 1U | 1U | 1U |
| Switching bandwidth (data rate, full duplex) | 1.28 Tbps | 1.28 Tbps | 1.28 Tbps |
| Switch performance | 960 Mpps | 960 Mpps | 960 Mpps |
| Port-to-port latency | 850 ns | 3 μs | 3 μs |
| Dimensions and weight | Width: 43.99 cm (17.32 in.) | Width: 43.74 cm (17.22 in.) | Width: 43.74 cm (17.22 in.) |
| Height: 4.32 cm (1.75 in.) | Height: 4.27 cm (1.68 in.) | Height: 4.27 cm (1.68 in.) | |
| Depth: 40.99 cm (16.14 in.) | Depth: 53.65 cm (21.12 in.) | Depth: 53.65 cm (21.12 in.) | |
| Weight: 8.66 kg (19.1 lb) | Weight: 10.82 kg (23.85 lb | Weight: 10.82 kg (23.85 lb | |
| 10 GbE SFP+ ports | Up to 64 | Up to 16 | Up to 16 |
| 162/4/8/16 Gbps Fibre Channel Flex Ports | Up to 32 (out of 64 10 GbE ports)Port types supported: E_Port (connecting to EX_Port only), F_Port, N_Port (Access Gateway mode) | 0 | 0 |
| 1/10 GBASE-T | 0 | 48 | 48 |
| 40 GbE QSFP+ (10 GbE breakout cable) | 4 | 4 | 4 |
| 10 GbE Ports on Demand (PoD) | 24, 32, 40, 48, 56, 64 | 24, 32, 40, 48, 56, 64 | N/A |
| 10 GbE Capacity on Demand (CoD) | N/A | N/A | 16, 32, 48 |
| Power supplies | Two hot-swappable, load-sharing | Two hot-swappable, load-sharing | Two hot-swappable, load-sharing |
| Cooling fans | N+1 redundant, integrated into power supplies | N+1 redundant, integrated into power supplies | N+1 redundant, five hot-swappable fan units |
| Airflow | Front to back Back to front | Front to back Back to front | Front to back Back to front |
| Connector Options | Out-of-band Ethernet management: RJ45 (fixed) Console management: RJ45 to RS-232 (fixed) Firmware and diagnostic: USB |
| Maximum VLANs | 4,096 |
| Maximum MAC addresses | 160,000 |
| Maximum port profiles (AMPP) | 1,024 |
| Maximum members in a standard LAG | 64 |
| Maximum per-port priority pause level | 8 |
| Maximum switches that a vLAG can span | 8 |
| Maximum members in a vLAG | 64 |
| Maximum jumbo frame size | 9,216 bytes |
| Queues per port | 8 |
| DCB Priority Flow Control (PFC) classes | 8 |
| Maximum ACLs | 13,000 |
| Maximum ARP entries | 32,000 |
| Maximum IPv4 unicast routes | 12,000 |
| Maximum IPv6 unicast routes | 3,000 |
| HA/ISSU | ISSU fully supported |
| Enclosure | Front-to-rear, rear-to-front airflow; 1U, 19-inch EIA-compliant; power from non-port side |
| Temperature | Operating: 0°C to 40°C (32°F to 104°F) Non-operating and storage: -25°C to 70°C (-13°F to 158°F) |
| Humidity | Operating: 10% to 85% non-condensing Non-operating and storage: 10% to 90% non-condensing |
| Altitude | Operating: Up to 3,048 meters (10,000 feet) Non-operating and storage: Up to 12 kilometers (39,370 feet) |
| Shock | Operating: 20 G, 11 ms half-sine Non-operating and storage: Square wave, 44 G, 15 ms |
| Vibration | Operating: 0.5 G peak, 0.7 G ms random, 5 to 500 Hz Non-operating and storage: 2.0 g sine, 1.4 G rms random, 5 to 500 Hz |
| Airflow | VDX 6740T port-side-intake: Maximum: 49.3 CFM; Nominal: 26.3 CFMB VDX 6740T port-side-exhaust: Maximum: 51.9 CFM; Nominal: 27.3 CFM VDX 6740 port-side-intake and port-side-exhaust: Maximum: 25.7 CFM; Nominal: 11.5 CFM |
| Heat dissipation | 1,672.41 BTU/hr |
| Power supplies | Two internal, redundant, field-replaceable, load-sharing AC power supplies |
| Power inlet | C13 |
| Input voltage | 85 to 264 VAC nominal |
| Input line frequency | 50 to 60 Hz |
| Inrush current | Limited to 30 A peak at 240 VAC during cold startup at 25°C ambient |
| Maximum current | 6 A max at 100 VAC/60 Hz |
| Maximum power consumption | VDX 6740: 110 W VDX 6740T: 460 W VDX 6740T-1G: 276 W (Base SKU) |
| CAN/CSA C22.2 No. 60950-1-07 including A1 / UL 60950-1-07, Ed. 2 including A1 |
| CAN/CSA-C22.2 No. 60950-1 Second Edition |
| EN 60950-1 Second Edition +A1/A12 |
| IEC 60950-1 Second Edition +A1•GB 4943.1-2011 and GB9254-2008 |
| CNS14336-1(99) |
| FCC Class A |
| ICES-003 Class A |
| VCCI-Class A |
| CE |
| C-Tick |
| BSMI |
| GOST |
| KCC Class A |
| CCC |
| ANSI C63.4 |
| ICES-003 Class A |
| CISPR22 and JEIDA (Harmonics) |
| EN55022 Class A and EN55024 |
| CISPR22 |
| AS/NZS CISPR22 |
| CNS 13438(95) |
| 51318.22-99 and 51318.24-99 |
| KN22 and KN24 |
| GB17625.1-2003 |
| RoHS-6 (with lead exemption) Directive 2002/95/EC |
| VDX 6740 products conform to the following Ethernet standards: |
| IEEE 802.1D Spanning Tree Protocol |
| IEEE 802.1s Multiple Spanning Tree |
| IEEE 802.1w Rapid Reconfiguration of Spanning Tree Protocol |
| IEEE 802.3 Ethernet |
| IEEE 802.3ad Link Aggregation with LACP |
| IEEE 802.3ae 10G Ethernet |
| IEEE 802.1Q VLAN Tagging |
| IEEE 802.1p Class of Service Prioritization and Tagging |
| IEEE 802.1v VLAN Classification by Protocol and Port |
| IEEE 802.1AB Link Layer Discovery Protocol (LLDP) |
| IEEE 802.3x Flow Control (Pause Frames) |
| IEEE 802.3ab 1000BASE-T |
| IEEE 802.3z 1000BASE-X |
| The following draft versions of the Data Center Bridging (DCB) and Fibre Channel over Ethernet (FCoE) standards are also supported on the VDX 6740: |
| IEEE 802.1Qbb Priority-based Flow Control |
| IEEE 802.1Qaz Enhanced Transmission Selection |
| IEEE 802.1 DCB Capability Exchange Protocol (Proposed under the DCB Task Group of IEEE 802.1 Working Group) |
| FC-BB-5 FCoE (Rev 2.0) |
| The VDX 6740 products conform to the following Fibre Channel standards: |
| FC-GS-5 ANSI INCITS 427:2007 (includes the following) –FC-GS-4 ANSI INCITS 387: 2004 |
| FC-SP-2 INCITS 496-2012(AUTH-A, AUTH-B1 only) |
| FC-DA INCITS TR-36: 2004 (includes the following) –FC-FLA INCITS TR-20: 1998–FC-PLDA INCIT S TR-19: 1998 |
| FC-MI-2 ANSI/INCITS TR-39-2005 |
| FC-PI INCITS 352: 2002 |
| FC-PI-2 INCITS 404: 2005 |
| FC-PI-4 INCITS 1647-D, revision 7.1 (under development) |
| FC-FS-2 ANSI/INCITS 424:2006 (includes the following) –FC-FS INCITS 373: 2003 |
| FC-LS INCITS 433: 2007 |
| MIB-FA INCITS TR-32: 2003 |
| RFC 768 | User Datagram Protocol (UDP) |
| RFC 783 | TFTP Protocol (revision 2) |
| RFC 791 | Internet Protocol (IP) |
| RFC 792 | Internet Control Message Protocol (ICMP) |
| RFC 793 | Transmission Control Protocol (TCP) |
| RFC 826 | ARP |
| RFC 854 | Telnet Protocol Specification |
| RFC 894 | A Standard for the Transmission of IP Datagram over Ethernet Networks |
| RFC 959 | FTP |
| RFC 1027 | Using ARP to Implement Transparent Subnet Gateways (Proxy ARP) |
| RFC 1112 | IGMPv1 |
| RFC 1157 | Simple Network Management Protocol (SNMP) v1 and v2 |
| RFC 1305 | Network Time Protocol (NTP) Version 3 |
| RFC 1492 | TACACS+ |
| RFC 1519 | Classless Inter-Domain Routing (CIDR) |
| RFC 1584 | Multicast Extensions to OSPF |
| RFC 1765 | OSPF Database Overflow |
| RFC 1812 | Requirements for IP Version 4 Routers |
| RFC 1997 | BGP Communities Attribute |
| RFC 2068 | HTTP Server |
| RFC 2131 | Dynamic Host Configuration Protocol (DHCP) |
| RFC 2154 | OSPF with Digital Signatures (Password, MD-5) |
| RFC 2236 | IGMPv2 |
| RFC 2267 | Network Ingress Filtering |
| RFC 2328 | OSPF v2 |
| RFC 2370 | OSPF Opaque Link-State Advertisement (LSA) Option—Partial Support |
| RFC 2375 | IPv6 Multicast Address Assignments |
| RFC 2385 | Protection of BGP Sessions with the TCP MD5 Signature Option |
| RFC 2439 | BGP Route Flap Damping |
| RFC 2460 | Internet Protocol, Version 6 (v6) Specification (on management interface) |
| RFC 2462 | IPv6 Stateless Address Auto-Configuration |
| RFC 2464 | Transmission of IPv6 Packets over Ethernet Networks (on management interface) |
| RFC 2474 | Definition of the Differentiated Services Field in the IPv4 and IPv6 Headers |
| RFC 2571 | An Architecture for Describing SNMP Management Frameworks |
| RFC 2711 | IPv6 Router Alert Option |
| RFC 2865 | Remote Authentication Dial-In User Service (RADIUS) |
| RFC 3101 | The OSPF Not-So-Stubby Area (NSSA) Option |
| RFC 3137 | OSPF Stub Router Advertisement |
| RFC 3176 | sFlow |
| RFC 3392 | Capabilities Advertisement with BGPv4 |
| RFC 3411 | An Architecture for Describing SNMP Frameworks |
| RFC 3412 | Message Processing and Dispatching for the SNMP |
| RFC 3413 | Simple Network Management Protocol (SNMP) Applications |
| RFC 3587 | IPv6 Global Unicast Address Format |
| RFC 3623 | Graceful OSPF Restart—IETF Tools |
| RFC 3768 | VRRP |
| RFC 4271 | BGPv4 |
| RFC 4291 | IPv6 Addressing Architecture |
| RFC 4292 | IP Forwarding MIB |
| RFC 4293 | Management Information Base for the Internet Protocol (IP) |
| RFC 4443 | ICMPv6 (replaces 2463) |
| RFC 4456 | BGP Route Reflection |
| RFC 4510 | Lightweight Directory Access Protocol (LDAP): Technical Specification Road Map |
| RFC 4601 | Protocol Independent Multicast—Sparse Mode (PIM-SM): Protocol Specification (Revised) |
| RFC 4724 | Graceful Restart Mechanism for BGP |
| RFC 4861 | IPv6 Neighbor Discovery |
| RFC 4893 | BGP Support for Four-Octet AS Number Space |
| RFC 5082 | Generalized TTL Security Mechanism (GTSM) |
| RFC 5880 | Bidirectional Forwarding Detection (BFD) |
| RFC 5881 | Bidirectional Forwarding Detection (BFD) for IPv4 and IPv6 (Single Hop) |
| RFC 5882 | Generic Application of Bidirectional Forwarding Detection (BFD) |
| RFC 5883 | Bidirectional Forwarding Detection (BFD) for Multihop Paths |
| RFC 5942 | IPv6 Neighbor Discovery |
| RFC 7432 | BGP-EVPN—Network Virtualization Using VXLAN Data Plane |
| IPv6 Routing | |
| RFC 2545 | Use of BGP-MP Extensions for IPv6 |
| RFC 2740 | OSPFv3 for IPv6 |
| IPv6 Multicast | |
| RFC 2710 | Multicast Listener Discovery (MLD) for IPv6 |
| VRRP/VRRPe | |
| RFC 5798 | VRRP Version 3 for IPv4 and IPv6 |
| VCS Fabrics | IP Fabrics | ||
| Software scalability | Maximum switches in a fabric | 48 | Unlimited |
| Maximum ECMP paths in a fabric | 32 | 32 | |
| Maximum LAGs in a fabric | 2,000 | Unlimited | |
| Layer 2 switching | Service Node Load Balancing BFD/ARP Optimizations | X | X |
| Conversational MAC Learning | X | X | |
| Virtual Link Aggregation Group (vLAG) spanning | X | X | |
| Layer 2 Access Control Lists (ACLs) | X | X | |
| Supports 2K ingress and egress ACLs | X | X | |
| Edge Loop Detection (ELD) | X | X | |
| Address Resolution Protocol (ARP) RFC 826 | X | X | |
| Private VLANs | X | ||
| Maintenance Mode/Graceful Traffic Diversion | X | ||
| Distributed VXLAN Gateway | X | ||
| Diagnostic Ports | X | ||
| IP Maps Support | X | ||
| L2 Loop prevention in an overlay environment | X | ||
| High availability/In-Service Software Upgrade—hardware-enabled | X | X | |
| IGMP snooping support for multicast flooding | X | X | |
| IGMPv1/v2 Snooping | X | X | |
| IGMPv1/v2 Snooping | X | X | |
| IGMPv3 | X | X | |
| MAC Learning and Aging | X | X | |
| Link Aggregation Control Protocol (LACP) IEEE 802.3ad/802.1AX | X | X | |
| Virtual Local Area Networks (VLANs) | X | X | |
| VLAN Encapsulation 802.1Q | X | X | |
| Per-VLAN Spanning Tree (PVST+/PVRST+) | X | X | |
| Rapid Spanning Tree Protocol (RSTP) 802.1w | X | X | |
| Multiple Spanning Tree Protocol (MSTP) 802.1s | X | X | |
| STP PortFast, BPDU Guard, BPDU Filter | X | X | |
| STP Root Guard | X | X | |
| Pause Frames 802.3x | X | X | |
| Static MAC Configuration | X | X | |
| Uni-Directional Link Detection (UDLD) | X | X | |
| Uplink switch for VDX switches, VCS fabrics, and the VCS Virtual Fabric feature | X | ||
| Transparent LAN Services | X | ||
| L2 Traceroute for VXLAN | X | X | |
| BUM Storm Control | X | X | |
| Layer 3 switching | Border Gateway Protocol (BGP4+) | X | X |
| DHCP Helper | X | X | |
| Layer 3 ACLs | X | X | |
| Multicast: PIM-SM, IGMPv2 | X | X | |
| OSPF v2/v3 | X | X | |
| Static routes | X | X | |
| IPv4/v6 ACL | X | X | |
| IPv4/v6 ACL | X | X | |
| Policy-Based Routing (PBR) | X | X | |
| Bidirectional Forwarding Detection (BFD) | X | X | |
| 32-Way ECMP | X | X | |
| VRF Lite | X | X | |
| VRF-aware OSPF, BGP, VRRP, static routes | X | X | |
| VRRP v2 and v3 | X | X | |
| uRPF for IPv4 and IPv6 | X | ||
| IPv4/IPv6 dual stack | X | X | |
| IPv6 ACL packet filtering | X | X | |
| BGP automatic neighbor discovery for IP fabric | X | ||
| BGP Additional-Path | X | X | |
| BGP-Allow AS | X | X | |
| BGP Generalized TTL Security Mechanism (GTSM) | X | X | |
| BGP graceful shutdown for maintenance mode | X | ||
| BGP Peer Auto Shutdown | X | X | |
| Multicast Refactoring | X | X | |
| IPv6 routing | X | X | |
| OSPF Type-3 LSA Filter | X | X | |
| Wire-speed routing for IPv4 and IPv6 using any routing protocol | X | X | |
| BGP-EVPN Control Plane Signaling RFC 7432 | X | ||
| BGP-EVPN VXLAN Standard-based Overlay | X | ||
| Multi-VRF | X | X | |
| IP Unnumbered Interface | X | ||
| Intersubnet Routing (Symmetric and Asymmetric) | X | ||
| IP over Port Channel | X | ||
| VRRP-E | X | X | |
| Fabric Virtual Gateway | X | X | |
| Static Anycast Gateway | X | ||
| ARP Suppression | X | ||
| Automation and programmability | OpenFlow 1.3 | X | X |
| REST API with YANG data model | X | X | |
| Puppet | X | X | |
| Python | X | X | |
| PyNOS libraries | X | X | |
| VMware vRealize plugins | X | X | |
| DHCP automatic fabric provisioning | X | X | |
| Netconf API | X | X | |
| Mulititenancy and virtualization | TRILL FGL-based VCS Virtual Fabric feature | X | |
| Virtual fabric extension | X | ||
| VM-Aware Network Automation | X | ||
| BFD for virtual fabric extension | X | ||
| Automatic Migration of Port Profiles (AMPP) | X | X | |
| DCB | Priority-based Flow Control (PFC) 802.1Qbb | X | |
| Enhanced Transmission Selection (ETS) 802.1Qaz | X | ||
| Manual configuration of lossless queues for protocols other than FCoE and iSCSI | X | ||
| Data Center Bridging Exchange (DCBX) | X | ||
| DCBX Application Type-Length-Value (TLV) for FCoE and iSCSI | X | ||
| Fibre Channel/FCoE | Multi-hop Fibre Channel over Ethernet (FCoE); requires VCS Fabric technology | X | |
| FC-BB5 compliant Fibre Channel Forwarder (FCF) | X | ||
| Native FCoE forwarding | X | ||
| FCoE to Fibre Channel Bridging | X | ||
| FCoE on VDX 8770 | X | ||
| FCoE on QSFP+ port | X | ||
| Multi-hop Access Gateway Support | X | ||
| End-to-end FCoE (initiator to target) | X | ||
| FCoE Initialization Protocol (FIP) v1 support for FCoE device login and initialization | X | ||
| Name Server-based zoning | X | ||
| Supports connectivity to FIP Snooping Bridge (FSB) device | X | ||
| FCoE traffic over standard LAG | X | ||
| Interface Binding | X | ||
| Dual Personality Ports | X | ||
| Logical SANs | X | ||
| High availability | ISSU L2 and L3 | X | X |
| BFD | X | X | |
| OSPF3-NSR | X | X | |
| BGP4-GR | X | X | |
| Management Module Failover | X | X | |
| Quality of Service (QoS) | ACL-based QoS | X | X |
| Eight priority levels for QoS | X | X | |
| Class of Service (CoS) IEEE 802.1p | X | X | |
| DSCP Trust | X | X | |
| DSCP to Traffic Class Mutation | X | X | |
| DSCP to CoS Mutation | X | X | |
| DSCP to DSCP Mutation | X | X | |
| Random Early Discard | X | X | |
| Per-port QoS configuration | X | X | |
| ACL-based Rate Limit | X | X | |
| Dual-rate, three-color token bucket | X | X | |
| ACL-based remarking of CoS/DSCP/Precedence | X | X | |
| ACL-based sFlow | X | X | |
| Scheduling: Strict Priority (SP), Deficit Weighted Round-Robin (DWRR), Hybrid Scheduling (Hybrid) | X | X | |
| Queue-based Shaping | X | X | |
| Flow-based QoS | X | X | |
| Management and monitoring | Logical chassis management | X | |
| IPv4/IPv6 management | X | X | |
| Industry-standard Command Line Interface (CLI) | X | X | |
| Netconf API | X | X | |
| REST API with YANG data model | X | X | |
| VDX Plugin for OpenStack | X | X | |
| Link Layer Discovery Protocol (LLDP) IEEE 802.1AB | X | X | |
| MIB II RFC 1213 MIB | X | X | |
| Switch Beaconing | X | X | |
| Management VRF | X | X | |
| Switched Port Analyzer (SPAN) | X | X | |
| Telnet | X | X | |
| SNMP v1, v2C, v3 | X | X | |
| sFlow RFC 3176 | X | X | |
| Out-of-band management | X | X | |
| Remote SPAN (RSPAN) | X | X | |
| RMON-1, RMON-2 | X | X | |
| NTP | X | X | |
| Management Access Control Lists (ACLs) | X | X | |
| Role-Based Access Control (RBAC) | X | X | |
| Range CLI support | X | X | |
| UDLD | X | X | |
| OpenStack Neutron ML2 plugin | X | X | |
| Python | X | X | |
| Puppet | X | X | |
| Distributed Configuration Management | X | ||
| Maps switch health monitoring | X | ||
| Security | Port-based Network Access Control 802.1X | X | X |
| RADIUS (AAA) | X | X | |
| TACACS+ | X | X | |
| Secure Shell (SSHv2) | X | ||
| BPDU Drop X X | X | X | |
| Lightweight Directory Access Protocol (LDAP) | X | X | |
| Secure Copy Protocol | X | X | |
| Port Security | X | X |
| BR-VDX6740-24-F | VDX 6740, 24P SFP+ ports only—no optics, AC, non-port-side exhaust airflow |
| BR-VDX6740-24-R | VDX 6740, 24P SFP+ ports only—no optics, AC, port-side exhaust airflow |
| BR-VDX6740-48-F | VDX 6740, 48P SFP+ ports only—no optics, AC, non-port-side exhaust airflow |
| BR-VDX6740-48-R | VDX 6740, 48P SFP+ ports only—no optics, AC, port-side exhaust airflow |
| BR-VDX6740-64-F | VDX 6740, 64P SFP+ ports only—no optics, AC, non-port-side exhaust airflow |
| BR-VDX6740-64-R | VDX 6740, 64P SFP+ ports only—no optics, AC, port-side exhaust airflow |
| BR-VDX6740-64-ALLSW-F | VDX 6740, 64P SFP+ ports only—no optics, AC, FCoE, VCS fabric, non-port-side exhaust airflow |
| BR-VDX6740-64-ALLSW-R | VDX 6740, 64P SFP+ ports only—no optics, AC, FCoE, VCS fabric, port-side exhaust airflow |
| BR-VDX6740T-24-F | VDX 6740T, 24P 10GBASE-T ports only—no optics, AC, non-port-side exhaust airflow |
| BR-VDX6740T-24-R | VDX 6740T, 24P 10GBASE-T ports only—no optics, AC, port-side exhaust airflow |
| BR-VDX6740T-48-F | VDX 6740T, 48P 10GBASE-T ports only—no optics, AC, non-port-side exhaust airflow |
| BR-VDX6740T-48-R | VDX 6740T, 48P 10GBASE-T ports only—no optics, AC, port-side exhaust airflow |
| BR-VDX6740T-64-F | VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, non-port-side exhaust airflow |
| BR-VDX6740T-64-R | VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, port-side exhaust airflow |
| BR-VDX6740T-64-ALLSW-F | VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, FCoE, VCS fabric, non-port-side exhaust airflow |
| BR-VDX6740T-64-ALLSW-R | VDX 6740T, 48P 10GBASE-T and 4 SFP+ ports only—no optics, AC, FCoE, VCS fabric, port-side exhaust airflow |
| BR-VDX6740T-56-1G-F | VDX 6740T-1G, 48P 1000BASE-T and 2 40 GbE QSFP+ ports, upgradable to 10GBASE-T via license only—no optics, AC, non-port-side exhaust airflow |
| BR-VDX6740T-56-1G-R | VDX 6740T-1G, 48P 1000BASE-T and 2 40 GbE QSFP+ ports, upgradable to 10GBASE-T via license only—no optics, AC, port-side exhaust airflow |
| BR-VDX6740-8x10G-POD | 8-port PoD license for VDX 6740 and 6740T |
| BR-VDX6740-2x40G-POD | 2-port 40 GbE PoD license for VDX 6740 and 6740T |
| BR-VDX6740T-1G-16X10G-COD | 16-port 1 GbE to 10 GbE Capacity on Demand (CoD) upgrade license for VDX 6740T-1G |
| BR-VDX6740-FCoE | Software, FCoE license for VDX 6740 and 6740T |
| BR-VDX6740-VCS | Software, VCS license for VDX 6740 and 6740T |
| BR-VDX6740-ALLSW | Software, VCS and FCoE license for VDX 6740 and 6740T |
| XBR-250WPSAC-F | FRU 250 W AC power supply/fan, non-port-side exhaust airflow, VDX 6740 |
| XBR-250WPSAC-R | FRU 250 W AC power supply/fan, port-side exhaust airflow, VDX 6740 |
| XBR-500WPSAC-01-F | FRU 500 W AC power supply/fan, non-port-side exhaust airflow, VDX 6740T, 6740T-1G |
| XBR-500WPSAC-01-R | FRU 500 W AC power supply/fan, port-side exhaust airflow, VDX 6740T, 6740T-1G |
| XBR-AC-F | AN-FAC fan, non-port-side exhaust airflow, VDX 6740T, 6740T-1G |
| XBR-AC-FAN-R | AC fan, port-side exhaust airflow, VDX 6740T, 6740T-1G |
| XBR-R000291 | FRU, VDX 6740 fixed rack-mount kit for 4-post racks |
| XBR-R000292 | FRU, VDX 6740 mid-mount kit for 2-post racks |
| XBR-R000293 | Flush-mount kit for 2-post racks for VDX 6740 |
| XBR-R000294 | FRU, universal 2-post mid-mount kit/flush-mount kit, VDX 6740T/6740T-1G |
| XBR-R000295 | FRU, universal rack-mount kit, 4-post, 24- to 32-inch depth rack, VDX 6740T/6740T-1G |









MLX Series Router
CER 2000 Series Router
SLX 9850 Router
6910 Ethernet Access Switch
CES 2000 Series Switch
SLX 9540 Switch
SLX 9240 Switch
VDX 6940 Switch
VDX 8770 Switch